Shenton, H. W.
Guidelines for Pre-Qualification, Prototype and Quality Control Testing of Seismic Isolation Systems.
January 1996, 152 p.
Identifying Number(s): NISTIR-5800
Keywords: Bridges (Structures); Standards; Prototypes; Hybrid systems; Displacement; Elastomeric systems; Loads (Forces); Requirements; Qualification; Quality control; Vibration isolators; Earthquake resistant structures; Structural vibration; Vibration dampling; Sliding; Building codes; Test methods; Dynamic response; Earthquake engineering; Dynamic structural analysisShenton, H. W.
Draft Guidelines for Quality Control Testing of Elastomeric Seismic Isolation Systems.
February 1994, 30 p.
Identifying Number(s): NISTIR-5345
Keywords: ; Seismic design; Lateral forces; Buildings; Earthquake engineering; Quality control; Vibration isolators; Tests; Design criteriaTodd, D.; Anderson, E.; Carino, N.; Cheok, G.; Chung, R.; Gross, J.; Phan, L.; Schultz, A. E.; Shenton, H. W.; Taylor, A.; Yancey, C. W. C.
Performance of HUD-Affiliated Properties during the January 17, 1994 Northridge Earthquake.
Department of Housing and Urban Development, Washington, DC., August 1994, 60 p.
Identifying Number(s): NISTIR-5488
Keywords: Damage assessment; Southern Region (California); Nonstructural damage; Structural vibration; California; Earthquake damage; Dynamic response; Performance evaluation; Multifamily housing; US HUD; Soil structure interactions; Residential buildings; Structural damage; Seismic effects; Northridge Earthquake; Dynamic structural analysisShenton, H. W.
Draft Guidelines for Pre-Qualification and Prototype Testing of Seismic Isolation Systems.
March 1994, 103 p.
Identifying Number(s): NISTIR-5359
Keywords: ; Bridges (Structures); Earthquake resistant structures; Structural vibration; Standards; Prototypes; Test facilities; Test methods; Dynamic response; Earthquake engineering; Vibration damping; Displacement; Stiffness; Vibration isolators; Loads (Forces); Building codes; Dynamic structural analysisShenton, H. W.
Draft Guidelines for Quality Control Testing of Sliding Seismic Isolation Systems.
March 1994, 33 p.
Identifying Number(s): NISTIR-5371
Keywords: ; Bridges (Structures); Earthquake resistant structures; Standards; Structural vibration; Test methods; Dynamic response; Earthquake engineering; Energy dissipation; Vibration damping; Quality control; Displacement; Vibration isolators; Building codes; Dynamic structural analysisShenton, H. W.
Summary and Results of the NIST Workshop on Proposed Guidelines for Testing and Evaluation of Seismic Isolation Systems. Held in San Francisco, California on July 25, 1994.
January 1996, 43 p.
Identifying Number(s): NISTIR-5785
Keywords: Seismic design; Compression tests; Aging; Standards; Prototypes; Seismic isolation systems; Guidelines; Damping; Quality control; Vibration isolators; Earthquake resistant structures; Structural vibration; Meetings; Building codes; Design criteria; Test methods; Model tests; Dynamic response; Earthquake engineering