  • Shenton, H. W.
    Draft Guidelines for Pre-Qualification and Prototype Testing of Seismic Isolation Systems.
    March 1994, 103 p.
    Identifying Number(s): NISTIR-5359
    Keywords: ; Dynamic response; Building codes; Vibration isolators; Earthquake resistant structures; Earthquake engineering; Prototypes; Loads (Forces); Test methods; Structural vibration; Test facilities; Vibration damping; Stiffness; Displacement; Bridges (Structures); Standards; Dynamic structural analysis

  • Agbabian, M. S.; Adham, S. A.; Masri, S. F.; Avanessian, V.; Traina, I.
    U.S.-Japan Coordinated Program for Masonry Building Research: Out-of-Plane Dynamic Testing of Concrete Masonry Walls. Volume 2. Test Results.
    National Science Foundation, Washington, DC. Directorate for Engineering., July 1989, 167 p.
    Keywords: ; Response; Seismic detection; Dynamic tests; Masonry; Earthquakes; Test methods; Flexural strength; Reinforced concrete; Walls; Mathematical models; Design; Panels

  • Seible, F.; LaRovere, H. L.
    Summary on Pseudodynamic Testing.
    National Science Foundation, Washington, DC., February 1987, 53 p.
    Identifying Number(s): REPT-3.1(B)-1
    Keywords: Computer programs; Earthquake engineering; Dynamic tests; Test methods; PSDYN computer program; Structural vibration; Matrices (Mathematics); User manuals (Computer programs); Vibration damping; Computerized simulation; Mathematical models; Dynamic structural analysis

  • Shenton, H. W.
    Summary and Results of the NIST Workshop on Proposed Guidelines for Testing and Evaluation of Seismic Isolation Systems. Held in San Francisco, California on July 25, 1994.
    January 1996, 43 p.
    Identifying Number(s): NISTIR-5785
    Keywords: Dynamic response; Compression tests; Damping; Building codes; Vibration isolators; Earthquake resistant structures; Quality control; Meetings; Earthquake engineering; Test methods; Seismic design; Structural vibration; Prototypes; Guidelines; Design criteria; Model tests; Seismic isolation systems; Aging; Standards

  • Leiva, G.; Klingner, R. E.
    In-Plane Seismic Resistance of Two-Story Concrete Masonry Shear Walls with Openings.
    National Science Foundation, Washington, DC., August 1991, 319 p.
    Identifying Number(s): REPT-3.1(C)-2
    Keywords: Grout; Failure; Computer programming; Earthquake resistant buildings; Masonry; Loads (Forces); Test methods; Instrumentation; Flexural strength; Reinforced concrete; Walls; Strain measurement; Structural members; Design criteria; Construction; Axial stress; Mathematical models; Coupled walls; Deformation; Shear stress; Cantilever walls

  • Shenton, H. W.
    Draft Guidelines for Quality Control Testing of Sliding Seismic Isolation Systems.
    March 1994, 33 p.
    Identifying Number(s): NISTIR-5371
    Keywords: ; Dynamic response; Dynamic structural analysis; Building codes; Vibration isolators; Quality control; Earthquake resistant structures; Earthquake engineering; Test methods; Structural vibration; Vibration damping; Displacement; Bridges (Structures); Standards; Energy dissipation

  • Liang, Z.; Tong, M.; Lee, G. C.
    Real-Time Structural Parameter Modification (RSPM): Development of Innervated Structures.
    National Science Foundation, Arlington, VA.; New York State Science and Technology Foundation, Albany., April 11, 1995, 108 p.
    Identifying Number(s): NCEER-95-0012
    Keywords: Dynamic structural analysis; Earthquake engineering; Models; Test methods; Vibration; Feedback control; Controllers; Seismic waves

  • Shenton, H. W.
    Guidelines for Pre-Qualification, Prototype and Quality Control Testing of Seismic Isolation Systems.
    January 1996, 152 p.
    Identifying Number(s): NISTIR-5800
    Keywords: Dynamic structural analysis; Dynamic response; Building codes; Vibration isolators; Earthquake resistant structures; Earthquake engineering; Sliding; Prototypes; Test methods; Structural vibration; Hybrid systems; Loads (Forces); Requirements; Quality control; Elastomeric systems; Displacement; Vibration dampling; Bridges (Structures); Standards; Qualification

  • Merryman, K. M.; Leiva, G.; Antrobus, N.; Klingner, R. E.
    In-Plane Seismic Resistance of Two-Story Concrete Masonry Coupled Shear Walls.
    National Science Foundation, Washington, DC., May 1990, 190 p.
    Identifying Number(s): REPT-3.1(C)-1
    Keywords: ; Floors; Performance evaluation; Grout; Reinforcing steels; Masonry; Test methods; Roofs; Earthquake resistance buildings; Joints (Junctions); Walls; Diagrams; Photographs; Design criteria; Construction; Precast concrete; Concrete blocks; Deformation; Shear stress; Reinforced concretes; Compressive strength